I don't know if you have this, but it can be very useful_
_________________________________
MSX-BASIC-KUN (BASIC COMPILER)
by J.Suzuki 1989
this document & samples by Sho Endo
translate to english by LASP
this text file typed without changes by Nestor Soriano
MSX-BASIC-KUN is an incredible BASIC compiler. It will compile a BASIC
program on memory in few seconds and execute it 15 to 100 times faster!! It
can compile most of the statements and functions of MSX-BASIC and can handle
strings and floating numbers. Once you see it, you'd feel you'd never need to
learn the Z-80 machine language. Real time games, C.G., demo programs can be
written by the ease of BASIC for machine language speed.
*** USAGE ***
1. Settings & General knowledge
This compiler is sold in Japan as a cartridge for 4500 yen. You just set it
in a slot to use it. Also, you can found this compiler in MSX2+ Sanyo
machines, in ROM.
Now you are in BASIC mode as usual, except that two commands are available:
CALL RUN
CALL TURBO ON/OFF
"CALL" can be written as "_" (underscore). I will ise that from now on.
_RUN is the command to compile and execute the entire program on memory. If
it finds an error it will stop and yield the message.
_TURBO ON is the statement to define the beginning of the turbo block.
_TURBO OFF is the end of the block.
The turbo block is the part of the program you want to execute fast. When the
entire program contains some uncompilable statements, you can define the
block to be compiled using this set.
EXAMPLE
100 SCREEN 8:DEFINT A-Z
110 BLOAD"PICTURE",S
120 _TURBO ON
130 FOR X=0 TO 255
140 LINE(X,0)-(X,211),0
150 NEXT X
160 _TURBO OFF
170 GOTO 170
This program cannot be "_RUN", because the "BLOAD" is one of the commands
that cannot be compiled. If you "RUN" this, the part lines 130 through 150
will be executed fast.
As '_RUN"FILE"' is not supported, you have to add _TURBO ON and _TURBO OFF at
the beginning and the end if you want to RUN"FILE" and have the effect.
100 FOR I=0 TO 999
110 ...
.
.
.
890 'END OF THE PROGRAM
So, this can be _RUN or add 10 _TURBO ON and 900 _TURBO OFF and RUN"FILE".
If you _RUN a program containing "_TURBO ON/OFF" it will be an error.
_TURBO ON/OFF can not be written in a multi-statement lines.
_TURBO ON/OFF can not be nested. But you may have many closed blocks in a
program.
Variables and arrays are handled differently in and outside of the blocks.
Once you are out of the block, variables and arrays used in the block are
lost. Only, the integer types can be defined as common.
100 DEFINT A-Z:DIM C(2),D(2)
110 A=1:B=2:C(0)=3:D(0)=4
120 _TURBO ON(A,C())
130 DIM D(2)
140 PRINT A,B,C(0),D(0)
150 A=5:B=6:C(0)=7:D(0)=8
160 _TURBO OFF
170 PRINT A,B,C(0),D(0)
RUN
1 0 3 0
5 2 7 4
Ok
Floating numbers used by the compiler is a special format 3-byte value. It's
accuracy is about 4.5 digits. Double precision is not available.
An array must be declared by a constant in the beginning.
This compiler works on the BASIC program on the RAM and creates the objects
and variables on the left RAM. So there is a limit of the size of the source
program about 10K. Big arrays, string variables (each uses 256 byte), CLEAR
,&H?
will make the situation tighter as you can imagine. The compiled
objects can not be saved as independent programs.
Interrupts available, such as KEY(1) ON, OFF etc. But it will decrease the
efficiency of the executed object's size & speed.
Some statements may not work correctly.
100 GOTO 130
110 A=3/2
120 END
130 DEFINT A-Z
140 GOTO 110
If you RUN this, A is 1. If you _RUN this, A is 1.5. DEF??? will be effective
when encountered during the execution in the case of interpreter, while it
depends on the order of line number in the other case.
A little complicated string operation may cause easily a "String formula too
complex" error. As this compiler has only one level of stack for it. Break a
long string formula into multiple small ones, if so.
If you _RUN an endless program, you can not stop it. Make a part to check
keyboards.
100 GOTO 100 'Reset or power off to stop
100 IF INKEY$="" THEN 100
110 END
is better.
2. Difference from MSX-BASIC interpreter
List of statements, commands and functions that can not be compiled.
AUTO, BASE, BLOAD, BSAVE, CALL, CDBL, CINT, CLEAR, CLOAD, CLOAD?, CLOSE,
CONT, CSAVE, CSNG, CVD, CVI, CVS, DEFFN, DELETE, DRAW, DSKF, EOF, ERASE, ERL,
ERR, ERROR, EQV, FIELD, FILES, FPOS, FRE, GET, IMP, INPUT#, KEY LIST, LFILES,
LINEINPUT#, LIST, LLIST, LOAD, LOC, LOF, LPRINT USING, LSET, MAXFILES, MERGE,
MOTOR, MKD$, MKI$, MKS$, NAME, NEW, ON ERROR GOTO, ON INTERVAL GOSUB (due to
a bug), OPEN, PLAY, PRINT#, PRINT USING, PUT KANJI, RENUM, RESUME, RSET,
SAVE, SPC, TAB, TRON, TROFF, WIDTH.
List of those with limits.
CIRCLE: Start, end angles and aspect ratio can't be specified.
COPY: Only graphic COPY is available.
DEFDBL: Same as DEFSNG.
DIM: Must come first in the program or in the turbo block.
INPUT: Can handle only one variable at the time.
KEY: ON KEY GOSUB, KEY(n) ON/OFF only.
LOCATE: x,y must be given in as a set. No cursor switch parameter.
NEXT: Variable names after the NEXT can not be omitted.
ON: ON STOP GOSUB, ON INTERVAL GOSUB not available.
PRINT: Commas work in a different way. No wrapping for digits.
PUT: PUT SPRITE only.
RUN: Variables won't be initialized.
SCREEN: Screen mode and sprite size only.
SET: SET PAGE only.
STOP: Same as END.
USR: Parameter type must be integer only.
VARPTR: File number can not be given as the parameter.
Otherwise there is no significant difference.
In general, I/O commands & functions, and editing commands can not be
compiled. Of course they are available in the direct mode, and outside of the
turbo block. You can edit, debug and save a program in MSX-BASIC and execute
it by _RUN.
If you want to use PRINT# to write characters on GRP:, use it outside of
turbo block. Otherwise study the sample, "PRINT.TRB".
If you want to use PLAY, use BGM compiler, and get the sound by USR(n).
3. New features added
3 special commands are available by starting a remark line with some specific
characters.
#I
Stands for INLINE. You can write a short machine-language routine.
100 DEFINT A-Z
110 K=1
120 '#I &H2A,K
130 '#I &HF3,&HCD,@150,&HFB
140 END
150 'SUB
160 RETURN
120 means LD HL,(K); K must be a simple variable of integer type.
130 means DI
CALL @150 ;Be careful, this line won't be RENUMed.
EI
#C
Stands for CLIP. In the screen modes 5 through 8 (except for PAINT, and
CIRCLE), this will be set clipping on and off.
10 SCREEN 8
20 '#C-
30 LINE(0,0)-(255,255) 'Y CLIPPED
40 IF INKEY$="" THEN 40
50 '#C+
60 LINE(0,0)-(255,255) 'NOT CLIPPED
70 IF INKEY$="" THEN 70
#N
Check if NEXT overflows.
10 FOR I%=0 TO &H7FFF
20 NEXT I%
This program will end up in a "Overflow error" in MSX-BASIC. And if _RUN, it
will be an endless loop. If #N+ is specififed, it will end normally. This
code will decrease the efficiency of the object, too. Better not use unless
it's really necessary. To clear, specify #N-.
NOTE: In MSX-2+ Sanyo you can found a new command:
CALL BC
This command turn on the BASIC COMPILER options.
_________________________________